Mining-pumping-systems-application-engineering

Effective pump maintenance allows industrial plants to keep pumps operating well, to detect problems in time to schedule repairs, and to avoid early pump failures. Regular maintenance also reveals deteriorations in efficiency and capacity, which can occur long before a pump fails. Wear ring and rotor erosions, for example, can be costly problems that reduce wire-to-water efficiency by 10% or more. 

The amount of attention given to maintenance depends on how important a system is to a plant’s operations. Downtime can be expensive when it affects critical processes. Most maintenance activities can be classified as either preventive or predictive. Preventive maintenance addresses routine system needs such as lubrication, periodic adjustments, and removal of contaminants. Predictive maintenance focuses on tests and inspections that detect deteriorating conditions.

Preventive Actions

Preventive maintenance activities include coupling alignment, lubrication, and seal maintenance and replacement. Mechanical seals must be inspected periodically to ensure that either there is no leakage or that leakage is within specifications. Mechanical seals that leak excessively usually must be replaced. A certain amount of leakage is required, however, to lubricate and cool the packing seals. But the packing gland needs to be adjusted if the leakage exceeds the manufacturer’s specifications. The packing gland must be replaced if it has to be tightened excessively to control leakage. Overtightening causes unnecessary wear on the shaft or its wear sleeve and increases electric power use. Routine maintenance of pump motors, such as proper lubrication and cleaning, is also vital.

Predictive Actions

Predictive maintenance helps minimize unplanned equipment outages. Sometimes called “condition assessment” or “condition monitoring,” it has become easier with modern testing methods and equipment. The following methods apply to pumping systems:

Vibration analysis. Trending vibration amplitude and frequency can detect an impending bearing failure. It can also reveal voltage and mechanical imbalances that could be caused by impeller erosion or coupling problems. Changes in vibration over time are more meaningful than a single “snapshot” of the vibration spectrum.

Motor current signature analysis. Sometimes called “dynamic analysis,” this reveals deteriorating insulation, rotor bar damage, electrical system unbalance, and harmonics. It can also pick up system problems such as malfunctioning control valves that cause flow rate disturbances. Tracking the signature over time is more valuable than a single snapshot.

Lubrication oil analysis. This applies only to large, oil-lubricated pumps, and is an expensive procedure. Oil analysis can detect bearing problems caused by metal particles or chemical changes that result from overheating, and seal problems caused by pumped fluid in the oil. It also provides guidance on proper oil-change intervals. 

Periodic efficiency testing. Testing the wire-to-water efficiency and keeping records to spot trends is useful.

Finally, see the checklist of maintenance items below, which can be tailored for many kinds of systems, applications, and facilities.

Basic Maintenance Checklist

  • Packing. Check for leakage and adjust according to the instructions of the pump and packing manufacturers. Allowable leakage is usually 2 to 60 drops per minute. Add packing rings or, if necessary, replace all the packing.
  • Mechanical Seals. Check for leakage. If leakage exceeds the manufacturer’s specifications, replace the seal.
  • Bearings. Determine the condition of the bearing by listening for noises that indicate excessive wear, measuring the bearing’s operating temperature, and using a predictive maintenance technique such as vibration analysis or oil analysis. Lubricate bearings according to the pump manufacturer’s instructions; replace them if necessary.
  • Motor/Pump Alignment. Determine if motor/pump alignment is within the service limits of the pump.
  • Motor Condition. Check the integrity of motor winding insulation. These tests usually measure insulation resistance at a certain voltage or the rate at which an applied voltage decays across the insulation. A vibration analysis can also indicate certain conditions within motor windings and lead to early detection of developing problems.

Suggested Actions

Establish a pumping system maintenance program that includes the following:

  • Preventive actions
  • Predictive actions
  • Periodic efficiency testing.
 
About Jonathon Bell

Jonathon Bell is an entrepreneur, focused on building his family's legacy in the industrial pump market.  Currently, he is focused in Latin America, building Dynapro Pumps Mexico from the ground up while contributing in Canada & the United States with Sales & Marketing efforts.

His commitment is developing teams through individual and partnered coaching, to bring out the best in each team member and giving them the tools to help them reach their goals. Guiding and teaching the core values of passion, evolving, and team communication, his teams and members become top performers in their respective fields.

He is honest, generous, and passionate about others success for them individually, their families, and their communities

About Dynapro:

A professional, trustworthy company, committed to create and maintain lasting relationships with our customers and our community.  Our focus is on constantly evolving our business practices and dedicated service to always be aligned with our clients and the environment.  

Our strong sense of responsibility to the environment and the communities we live and work in help encourage our clients and other companies to join forces with us to make a difference.  

We manufacture our own pump models and interchangeable high quality products, improve products, and materials.  We deliver them for less and faster to help achieve our goal of reduced consumption; energy & materials, and reduce maintenance.

For more information, please visit https://www.dynaproequipment.com/about-us.html

References

DOE/GO-102005-2159 September 2005 Pumping Systems Tip Sheet #5

Extend Your Motor’s Operating Life, DOE Motor Systems Tip Sheet, 2005. Test for Pumping System Efficiency, DOE Pumping Systems Tip Sheet, 2005.

Industrial Technologies Program Energy Efficiency and Renewable Energy

U.S. Department of Energy Washington, DC 20585-0121 www.eere.energy.gov/industry